This study aimed to to evaluate the stability of commonly used endogenous control genes for messenger RNA (mRNA) (N = 16) and miRNAs (N = 3) expression studies in prostate cell lines following irradiation. The stability of endogenous control genes expression in irradiated (6 Gy) versus unirradiated controls was quantified using NormFinder and coefficient of variation analyses. HPRT1 and 18S were identified as most and least stable endogenous controls, respectively, for mRNA expression studies in irradiated prostate cells. SNORD48 and miR16 miRNA endogenous controls tested were associated with low coefficient of variations following irradiation (6 Gy). This study highlights that commonly used endogenous controls can be responsive to radiation and validation is required prior to gene/miRNAs expression studies.
H Lawlor, Armelle Meunier, Niamh McDermott, Thomas Lynch and Laure Marignol
Download Paper
Resources
Area of Interest: Radiation Research
Acceptance, commissioning and clinical use of the WOmed T-200 kilovoltage X-ray therapy unit
OBJECTIVE: The objective of this work was to characterize the performance of the WOmed T-200-kilovoltage (kV) therapy machine. METHODS: Mechanical functionality, radiation leakage, alignment and interlocks were investigated. Half-value layers (HVLs) (first and second...
Comprehensive quality assurance phantom for the small animal radiation research platform (SARRP)
PURPOSE: To develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the Small Animal Radiation Research Platform (SARRP). METHODS AND MATERIALS: A QA phantom was developed for carrying out daily, monthly and annual QA...
Semi-automatic cone beam CT segmentation of in vivo pre-clinical subcutaneous tumours provides an efficient non-invasive alternative for tumour volume measurements
OBJECTIVE: To evaluate the feasibility and accuracy of using cone beam CT (CBCT) scans obtained in radiation studies using the small-animal radiation research platform to perform semi-automatic tumour segmentation of pre-clinical tumour volumes. METHPOD: Volume...
Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research
PURPOSE: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways...
Magnetic nanoparticle hyperthermia enhances radiation therapy: A study in mouse models of human prostate cancer.
PURPOSE: We aimed to characterise magnetic nanoparticle hyperthermia (mNPH) with radiation therapy (RT) for prostate cancer. METHODS: Human prostate cancer subcutaneous tumours, PC3 and LAPC-4, were grown in nude male mice. When tumours measured 150 mm3 magnetic iron...
Role of Interleukin-1 in Radiation-Induced Cardiomyopathy
Thoracic X-ray therapy (XRT), used in cancer treatment, is associated with increased risk of heart failure. XRT-mediated injury to the heart induces an inflammatory response leading to cardiomyopathy. The aim of this study was to determine the role of interleukin...
MRI-Only Based Radiotherapy Treatment Planning for the Rat Brain on a Small Animal Radiation Research Platform (SARRP).
Computed tomography (CT) is the standard imaging modality in radiation therapy treatment planning (RTP). However, magnetic resonance (MR) imaging provides superior soft tissue contrast, increasing the precision of target volume selection. We present MR-only based RTP for a rat brain on a small animal radiation research platform (SARRP) using probabilistic voxel classification with multiple MR sequences. Six rat heads were imaged, each with one CT and five MR sequences. The MR sequences were: T1-weighted, T2-weighted, zero-echo time (ZTE), and two ultra-short echo time sequences with 20 μs (UTE1) and 2 ms (UTE2) echo times. CT data were manually segmented into air, soft tissue, and bone to obtain the RTP reference. Bias field corrected MR images were automatically segmented into the same tissue classes using a fuzzy c-means segmentation algorithm with multiple images as input. Similarities between segmented CT and automatic segmented MR (ASMR) images were evaluated using Dice coefficient. Three ASMR images with high similarity index were used for further RTP. Three beam arrangements were investigated. Dose distributions were compared by analysing dose volume histograms. The highest Dice coefficients were obtained for the ZTE-UTE2 combination and for the T1-UTE1-T2 combination when ZTE was unavailable. Both combinations, along with UTE1-UTE2, often used to generate ASMR images, were used for further RTP. Using 1 beam, MR based RTP underestimated the dose to be delivered to the target (range: 1.4%-7.6%). When more complex beam configurations were used, the calculated dose using the ZTE-UTE2 combination was the most accurate, with 0.7% deviation from CT, compared to 0.8% for T1-UTE1-T2 and 1.7% for UTE1-UTE2. The presented MR-only based workflow for RTP on a SARRP enables both accurate organ delineation and dose calculations using multiple MR sequences. This method can be useful in longitudinal studies where CT’s cumulative radiation dose might contribute to the total dose.
Shandra Gutierrez, Benedicte Descamps, Christian Vanhove
Download Paper
Small animal image-guided radiotherapy: status, considerations and potential for translational impact.
Radiation biology is being transformed by the implementation of small animal image-guided precision radiotherapy into pre-clinical research programmes worldwide. We report on the current status and developments of the small animal radiotherapy field, suggest criteria...